Rheem RA1460AJ1NA — Air Conditioner - Rheem Classic Series RA14

Quick maintenance guide

Share
Own this appliance? Track it free in HomeBase

Quick Specs

Model NumberRA1460AJ1NA
Tonnage5.0 tons
SEER Rating14.00
EER Rating11.70
RefrigerantR-410A
Compressor TypeScroll
Operating Voltage208/230 volts single-phase 60 Hz
Maximum Overcurrent Protection50 amps
Minimum Circuit Ampacity32 amps
Compressor Rated Load Amps23.7 amps
Compressor Locked Rotor Amps152.5 amps
Outdoor Coil Net Face Area21.5 sq in
Outdoor Coil Number of Rows1
Outdoor Coil Fins per Inch22
Outdoor Fan Diameter26 inches
Outdoor Fan Number of Blades3
Outdoor Fan Motor1/5 hp
Outdoor Fan CFM4139 CFM
Outdoor Fan RPM850
Outdoor Fan Motor Watts254 watts
Operating Weight240 lbs
Shipping Weight247 lbs
Height35 inches
Length35.75 inches
Width35.75 inches
Liquid Line OD3/8 inches
Suction Line OD7/8 inches
Refrigerant Charge162 oz
Sound Power Level75.0 dBA
Cooling Capacity57000 BTU/H
Low Ambient CapabilityDown to 0°F with optional kit
Long Line CapabilityUp to 250 feet total equivalent length

Maintenance Schedule

TaskHow OftenDifficultyEst. Time
Coil cleaningAnnually or as needed to maintain performanceMediumVariable
Check and clean louver panelsSeasonallyEasy15-30 minutes
Inspect refrigerant lines for leaksSeasonallyMedium30 minutes
Verify all fasteners are secureAnnuallyEasy15 minutes
Check outdoor fan operationSeasonallyEasy10 minutes
Inspect compressor and connectionsAnnuallyMedium30 minutes
Verify control box connectionsAnnuallyMedium20 minutes

Filters & Parts

Filter Drier

Part #Field installed - part number not specified in manual

Compressor Crankcase Heater

Part #44-17402-45

Low Ambient Control Kit

Part #RXAD-A08

Compressor Sound Cover

Part #68-23427-25

Compressor Hard Start Kit

Part #SK-A1

Compressor Time Delay

Part #RXMD-B01

Low Pressure Control

Part #RXAC-A07

High Pressure Control

Part #RXAB-A07

Liquid Line Solenoid Valve

Part #200RD3T3TVLC

Solenoid Coil 24 VAC

Part #61-AMG24V

Solenoid Coil 120/240 VAC

Part #61-AMG120/240V

Classic Top Cap with Label

Part #91-101123-21

Decorative Top Cap

Part #Not specified

Troubleshooting

Unit making noise

Cause: Loose fasteners, vibration from compressor, or fan issues
Solution: Check and tighten all fasteners; inspect compressor mounting; verify fan operation
May require a professional

Reduced cooling capacity

Cause: Dirty coils, insufficient refrigerant charge, or airflow restriction
Solution: Clean outdoor coil; check for refrigerant leaks; verify adequate clearances around unit
May require a professional

Compressor not starting

Cause: Electrical connection issue, low voltage, or compressor failure
Solution: Verify proper electrical connections; check voltage at unit; inspect contactor and capacitor
May require a professional

High discharge temperature

Cause: Low refrigerant charge, dirty condenser coil, or restricted airflow
Solution: Check refrigerant level; clean coil; verify outdoor fan operation and clear blockages
May require a professional

Outdoor fan not running

Cause: Capacitor failure, motor failure, or electrical issue
Solution: Check capacitor voltage; inspect fan motor; verify electrical connections to fan

Reset Procedures

High/Low Pressure Switch Reset

  1. Turn off power to the unit
  2. Wait 5 minutes
  3. Restore power to the unit
  4. Unit should reset automatically when problem is cleared

Safety Warnings

Refrigerant R-410A is a high-pressure fluid. Do not attempt to service refrigerant components without proper EPA certification and recovery equipment.

Call a professional

Electrical shock hazard. Do not attempt electrical repairs. All electrical work must be performed by qualified technicians. Always disconnect power before servicing.

Call a professional

Unit contains moving parts including high-speed fan. Keep hands, loose clothing, and hair away from rotating components.

Call a professional

Do not apply capillary tube indoor coils to these units. Only use coils matched to this condenser for proper system operation.

Unit must be level in all horizontal planes for proper operation and oil return to compressor.

Ensure adequate ventilation around outdoor unit to prevent re-circulation of discharge air, especially when installing multiple units in enclosed areas.

Use only copper wire for electrical connections. Aluminum and clad aluminum connectors are not acceptable for this unit.

Factory-supplied filter drier must be installed. Do not operate system without proper filtration.

Maximum outdoor operating air temperature is 125°F. Do not operate unit in hotter ambient conditions.

Minimum outdoor operation air temperature for cooling mode without low-ambient accessory is 55°F.

Data sourced from the Rheem owner's manual.

View the full official manual

This guide is provided for informational purposes only. Always consult your official owner's manual before performing maintenance. HomeBase is not responsible for any damage resulting from the use of this information.